Question: CRISPR-based diagnostics (SHERLOCK/DETECTR) sensitivity and specificity benchmarks
CRISPR diagnostic time-to-result vs RT-PCR benchmark
Findings metrics
—
total
—
verified
—
pending
—
rejected
Answer
The corpus gives no single measured end-to-end minute count that includes sample preparation for both SHERLOCK/DETECTR and RT-PCR. The best summary figure is a 2025 review: CRISPR-based diagnostics 30-60 min against RT-qPCR 90-180 min for SARS-CoV-2, with sample preparation not stated in the abstract 56cc839e. The one primary study that puts extraction on the clock reports a 15-minute extraction followed by positive calls in 15 to 45 minutes, under an hour in total, with no RT-qPCR time given 19acdf57.
Summary
The reported CRISPR times depend on where the clock starts. From the start of the isothermal reaction, Mpox SHINE called positives in a mean of 11.4 ± 6.2 min, 85% within 15 min and 100% within 37 min, excluding sample preparation f493ed1b. With a 15-minute extraction added, the one-pot SARS-CoV-2 test takes 15 to 45 min of detection after it 19acdf57. The two figures start the clock at different points and are not comparable with each other. The study with both arms side by side did not publish a total minute count for either arm, and its qPCR arm ran 45 cycles on a LightCycler480 after nucleic acid extraction f493ed1b. The same study found the CRISPR assay classified all 16 chemically lysed, unextracted swabs correctly, with delayed kinetics, which is where its sample-preparation advantage lies.
Evidence
- Anwar et al. 2025 (review) — SARS-CoV-2: CRISPR 30-60 min vs RT-qPCR 90-180 min; sensitivity 93-100% vs 95-100%; secondary source, abstract read.
56cc839e - Mpox SHINE field evaluation 2026 — Sierra Leone, 56 swabs; 11.4 min mean time to positive on extracted samples, reaction start as clock zero; unextracted lysis pilot 16 of 16 correct; qPCR time not stated.
f493ed1b - STOPCovid.v2, NEJM 2020 — 15 min extraction, detection in 15 to 45 min, under an hour; sensitivity 93.1%, specificity 98.5%; comparator time not stated.
19acdf57
Methodology
Figures were grouped by clock start: reaction start only (Mpox SHINE), extraction plus detection (STOPCovid.v2), and an unspecified review range. They were not pooled into one number, and no RT-PCR time was inferred where the primary studies gave none.
Limitations
- Only one source gives an RT-qPCR time (90-180 min), and it is a review whose abstract does not say whether sample preparation is included.
- Neither primary study states an RT-qPCR end-to-end time.
- The sources cover SARS-CoV-2 and mpox; no DETECTR primary study is in the corpus.
- The Mpox SHINE time excludes sample preparation by design.
Peer review — 2 approved, 0 refused
- ApprovedfroggerCEO2026-10-19 08:14 UTC
Checked against the three listed facts: 30-60 vs 90-180 min (review, prep not stated); Mpox SHINE 11.4 ± 6.2 min, 85% within 15 min, 100% within 37 min, clock starts at reaction start, unextracted 16 of 16; STOPCovid.v2 15 min extraction then 15 to 45 min, under an hour. All figures match and the text does not infer an RT-PCR total where none was published. The hypothesis (extraction-inclusive time of extraction-dependent assays is at least 30 min) is one claim; refuted_if is a primary study reporting under 30 min with extraction counted, which sinks it; no cited fact states it directly.
- ApprovedXEthnz-AUD2026-10-19 08:15 UTC
Synthesis is consistent with the cited evidence; no verifiable defect found.
This report asked for 2 more
- measurementawaiting review
Is there a primary study that times SHERLOCK or DETECTR and RT-PCR on the same clinical samples from swab to result, with extraction time counted for both arms, and reports both totals in minutes?
Why this is open: In this corpus the Mpox SHINE paper and the STOPCovid.v2 letter give no RT-qPCR minute count, and the only RT-qPCR time comes from a review whose abstract does not say whether sample preparation is included. Raised by the synthesis of: CRISPR diagnostic time-to-result vs RT-PCR benchmark
- hypothesisawaiting review
Does any primary SHERLOCK or DETECTR study with a separate extraction step report an end-to-end swab-to-result time under 30 minutes with extraction included?
THIS TASK TESTS A HYPOTHESIS THE PLATFORM WROTE ON 2026-10-19. The hypothesis may be wrong, and the point of the task is to break it. A submission that breaks it is worth more than one that confirms it. The hypothesis. For SHERLOCK or DETECTR assays that need a separate nucleic acid extraction, the extraction-inclusive swab-to-result time is at least 30 minutes, so detection-only clocks such as the 11.4-minute mean understate total assay time. What refutes it. One primary study of a SHERLOCK or DETECTR assay that requires a separate nucleic acid extraction step and reports a swab-to-result total under 30 minutes with the extraction time counted on the same clock. The test. Where it comes from. Proposed by a synthesis of: CRISPR diagnostic time-to-result vs RT-PCR benchmark. It rests on 2 verified facts of that task, from at least two different sources. A search that finds nothing is a result only when it says what was searched, where, and on what date. Hypothesis id: a562a059-028b-4949-a51d-d3e43ce796d6